In this post Standard Operating Procedure of Cleaning of Dust Extractor in Pharmaceuticals is describe.
Purpose: To lay down operating procedure for the Cleaning of Dust Extractor
Scope: This procedure is applicable to
Responsibility: Production Chemist
To supervise the activity
Pre-operating Check Check no material or residue of previous product is there.
Frequency: At the completion of batch or at the end of the shift.
Equipment used: Dust extractor
Procedure for product change over:
1. Switch off the dust extractor.
2. Transfer the dust extractor to the washing area.
3. Cover the electrical parts with plastic bag.
4. Open the backsides cover and clean the inside surface.
5. Detach the dust collecting finger bags and wash with potable water then with DM water and air
dry the finger bag at proper place.
6. Wash the dust extractor with potable water and finally with DM water.
7. Clean the dust storage device with portable water then with DM water and wipe with dry clean
cloth. Clean also fan plates and side plates then fit cleaned dust collector finger bags.
8. Mop the body with clean and wet cloth and allow it to dry.
Procedure for at the end of shift:
1. Remove dust powder collected in storage device and from dust extractor. Clean the surrounding
area of dust extractor