In this post Standard Operating Procedure of SOP for Operation of Autocoater in Pharmaceuticals is describe.
Purpose: To lay down operating procedure for the operation of Autocoater.
Scope: This procedure is applicable for ..................
Responsibility: Production Chemist
To supervise the activity
Pre-operating Check: Check no material or residue should be there.
Equipment used: Autocoater (150 kg)
Operation:
1. Connect the silicon pipes to SS tank & the peristaltic pump.
2. Load the tablets into the pan.
3. Set the system operation serially as:
Press F3 DEFGHIJ s
4. Check the flow of automized spray by moving out the spray bar.
5. Start the stirrer.
6. Adjust the hot air & exhaust air pressure by adjusting hot air & Exhaust air damper controller.
7. Adjust the atomizing air & fan air pressure to 2kg/cm² & 3 kg/cm² Respectively.
8. Press spray air key K & peristaltic pump key L.
9. Adjust the RPM of the peristaltic pump as required.
10. Adjust the inlet, outlet & bed temperature & press ENTER.
11. To confirm the temperature setting, Press U once & Prev.SR twice.
12. Check the spray pattern, move the spray bar inside the pan .
13. Start the pan by adjusting the speed-adjusting knob.
14. At the end of the process, switch OFF the spray air, peristaltic Pump, atomizing & fan air knob.
PRECAUTIONS:
1. Before starting the operation, always check the clockwise rotation of the pan.
2. Check the insertion of silicon tubes in the peristaltic pump & check any twisting/folding in the silicon tubes.
3. Check the rotation of pressure roller for peristaltic pump.
4. While moving the spray bar inside the pan, keep the atomizing & Fan air pressure to zero & stop the spray bar key K & peristaltic Pump key L.
5. Do not touch key A 7 b during operation, when the system is in Manual.
6. Observe the alarm during the process & take the necessary action.