In this post Standard Operating Procedure of SOP for Operating and Cleaning of Stirrer in Pharmaceuticals is describe.
Purpose: To lay down procedure operating procedure for the Operation and Cleaning of stirrer.
Scope: This procedure is applicable for ................
Responsibility: Chemist
To supervise the activity
Pre- cleaning: Check that no material or residue should be there.
Frequency: For different product each time after use or at the end of the shift for the same product.
Procedure for cleaning:
1. Unscrew the propeller and rinse the rode and propeller with raw water and finally with
d.m. Water.
2. Clean the propeller and rod with brush to remove any residue of the previous product
and then wash with raw water and finally with DM. water.
3. After cleaning the stirrer collect the rinse water and send to QC lab. For swab
testing.
4. If the swab is not pass then reclean the stirrer till the sample of swab is
pass. If the swab pass by QA then attached the status label “CLEANED READY FOR USE”.