Title: Standard operating procedure of Methyl red
solution.
1.0 OBJECTIVE:
To
lay down the procedure of Methyl
red solution for Laboratory use.
2.0 SCOPE:
This
shall be applicable to the Quality Control Laboratory.
3.0 RESPONSIBILITY:
3.1
Q.C Pharmacist.
4.0 ACCOUNTABILITY:
4.1
Manager-Quality
Control.
4.2
Head of the Q.C
Department.
5.0 MATERIAL AND
EQUIPMENT:
5.1
Glassware (one 100.0ml
beaker, one stirrer, one pipette).
5.2
Magnetic stirrer.
5.3
50.0mg of methyl
red.
5.4
1.86ml of 0.1M
sodium hydroxide.
5.5
50.0ml of alcohol
R.
5.6
Purified water
q.s.
6.0 PROCEDURE:
6.1
Take a beaker of 100.0ml;
add 50.0mg of methyl red in it.
6.2
Add a mixture of
1.86ml of 0.1M sodium hydroxide and 50.0ml of alcohol R.
6.3
Mix it by using magnetic stirrer.
6.4
Dilute it to 100.0ml
with purified water R.
7.0 REVISION LOG:
Revision No.
|
Effective Date
|
Reason
|
00
|
|
New
SOP
|
8.0 REFERENCES:
8.1 The British Pharmacopoeia. Vol V. Appendix I, Official Monograph /General Reagent: 2015,
pp.19-141.
9.0 ANNEXURES:
9.1
Not Applicable.
10.0
ABBREVIATIONS:
Abbreviation
|
Expanded Form
|
SOP
|
Standard operating
procedure
|
&
|
And
|
No.
|
Number
|
Ltd.
|
Limited
|
Q.C
|
Quality control
|
QCR
|
Quality control reagent
|
ml
|
Milliliter
|
mg
|
Milligram
|
M
|
Molar
|
q.s.
|
Quantity sufficient
|
R
|
Reagent
|
Vol
|
Volume
|
No comments: